Vortex Flow Meter With Temperature And Pressure Compensation Recommendation
Author: PhilemonTime: 2023-05-11
Vortex Flow Meter With Temperature And Pressure Compensation
1. When vortex flowmeter detects gas, temperature and pressure should be compensated simultaneously; Gas is usually settled by volume flow in Standard temperature and pressure.
When the volume flow rate, temperature, or pressure of a gas changes, the flow rate will definitely change.
2. When detecting Superheated steam, the temperature and pressure shall be compensated at the same time; Steam is usually settled at mass flow rate.
Due to any change in temperature or pressure, the density of steam will change, and the mass flow rate will also change accordingly.